ADC Oil Burner

The Beckett ADC Oil Burner is designed for applications where an AC power source is not an option. Beckett GeniSys Control uses a suitable cad cell flame sensor to control the motor, igniter, and solenoid valve. Interrupted duty ignition extends battery life by
only drawing full load current during the ignition period.  Intermittent duty ignition is also available. Beckett CleanCut Pump has an integrated solenoid valve for smoother light-offs and cleaner shutdown. Air Guide provides high static pressure for smooth starts and minimal pulsation. Available in 12 V and 24 V configurations, the ADC burner is conveniently powered by a standard direct current power supply.

Capacities

  • “F” heads
  • 0.75 to 2.50 GPH
  • 105,000 to 350,000 BTU/hr input

Fuels

  • No. 1 or No. 2 diesel fuel or kerosene
  • No. 1 or No. 2 heating oil (ASTM D396) only

Fuel Unit

  • Single stage or two stage

Dimensions (standard)

  • Height: 11½”
  • Width: 14⅜”
  • Depth: 6 9/16
  • Air tube diameter: 4″

Electrical Characteristics

  • Motor: 13.5 VDC, ⅙hp, 3450 rpm, 10 amps (max.), NEMA M-flange, rotation CCW when facing shaft end.
  • Power Supply: 13.5 VDC
  • Ignition: 20 KVpk/30 mA interrupted duty OR optional continuous duty
  • Operating Load: 15 amps with igniter on, 8-10 amps with igniter turned off
  • Alternated Voltages or Frequency: Consult Customer Service

Ambient Operating Temperature

  • +32°F (0°C) Minimum
  • +115°F (+46°C) Maximum

Air Tube Combination Codes

Firing Rate GPH
(min-max)
HeadStatic Plate SizeATC Codes for Usable Air Tube Lengths
4½”5⅜”6⅝”
0.40-0.75F03⅜”AF44XRAF53XRAF65XR
0.75-1.25F32¾”AF44XNAF53XNAF65XN
0.85-1.35F42¾”AF44WHAF53WHAF65WH
0.85-1.65F62¾”AF44YBAF53YBAF65YB
1.10-2.00F122¾”AF44XOAF53XOAF65XO
1.65-2.50F222¾”AF44XPAF53XPAF56XP

ADC 12v Burner Manual