Features & Benefits
- Epoxy potted for moisture resistance
- Compatible with most operating controls
- Customizable pre-time and post-time
- Three status lights for system monitoring and diagnostics
- Welded relay protection with redundant motor relays
- Limited reset and limited recycle
- Sleek, modern design
- Technician pump prime mode
- 18 month warranty
- Communication ports for the GeniSys® Contractor Tool
Electrical Ratings
Inputs
-
- Voltage: 208-240 VAC
- Current: 100 mA plus burner motor, igniter, and valve loads
Outputs
-
- Motor: 208/240 Vac, 5 full load amps (FLA*), 30 locked rotor amps (LRA)
- Note: Reduce motor FLA rating by igniter current
- Igniter: 208/240 Vac, 3 A @ 0.7 PF min
- Solenoid Valve: 208/240 Vac, 1 A @ 0.7 PF min
- Motor: 208/240 Vac, 5 full load amps (FLA*), 30 locked rotor amps (LRA)
Application Ratings
-
- Oil Burner Input: less than 20gph
Environmental Ratings
-
- Storage & Operating Ambient Temperature: -40°F to +150°F (-40°C to +65°C)
- Moisture: 5 to 95%
Available Models for GeniSys® 7580 240V Oil Burner Control
| Control Part Number | Lockout Time | Valve-On Delay Time1 |
Motor-Off Delay Time1 |
| 7580A0000 | 15 sec | – | – |
| 7580B1500 | 15 sec | 15 sec | – |
| 7580P1515 | 15 sec | 15 sec | 15 sec |
| 7580P152M | 15 sec | 15 sec | 2 min |
| 7580P054M | 15 sec | 15 sec | 4 min |