This quick tutorial will guide you through the steps on priming pumps with the GeniSys Control installed.

1. Prepare the burner for priming

Hold the red reset button 15 seconds until the yellow light turns on and let go.

2. Push and release the red reset button

3. The yellow light will turn on...

and stay on for 4 minutes

4. Open the bleed port on the pump...

continue priming until a clear steady stream of oil is observed.

5. The Contractor Tool...

will display the time remaining during the priming process.

6. After priming is complete...

push and hold for 1 second to exit the pump prime mode.

Beckett Training is Now Online

Informative and technical training resources from the leading experts in the heating industry

We're Here to Help!

Have questions about our products? Looking for a solution to address a particular application? Looking to improve the overall productivity and profitability of your operation? Please don’t hesitate to reach out or schedule a no obligation, 1-on-1 consultation with a Beckett Technical Specialist — we’d love to help.