Burner Settings

(OEM Spec Guides)

Specifications for nozzles, air tube combinations, and other initial settings.

Tech Bulletins

Service bulletins and product updates.

Tutorials

Training videos and PowerPoint presentations.

Troubleshooting Guides

Solutions to common issues.

Find A Part

Look through exploded views to find the part you need.

Manuals & Guides

A library of product manuals and supplemental guides.

Product Warranty

View the limited warranty for all Beckett products.

Return Material Authorization

Submit a return material authorization (RMA) Request.

Warnings

(Proposition 65)

Frequently asked questions, and a list of affected products.

Classroom Training

Hands-on, practical installation, application, and operation training on Beckett’s latest products — in-person with the industry’s foremost authorities. Register today.

Online Training

Informative and technical training resources from the leading experts in the heating industry — now available online, on-demand, and FREE.

Product Instructional Videos

Our most popular product-related instructional / training videos for the most relevant and widely seen products and applications you’ll find in the field.

Residential Heating Solutions from Beckett®

For over 80 years Beckett products have been the number one choice of homeowners and contractors for their furnaces, boilers, and water heaters. As North America's foremost brand of burners, Beckett continues to provide industry leading design, reliability, and support. All backed by a comprehensive warranty program that ensures you will have years of trouble-free operation.

RF Oil Burner

RF Oil Burner

NEW! Designed to meet the many challenges of today’s modern heating appliances and process equipment, the Beckett RF oil burner is designed to ...
Commercial Heating/Steam Solutions from Beckett®

As North America's leading brand of burners, you can have peace of mind in using a Beckett burner on your next commercial project. With the environment in mind, we have the most comprehensive lineup of biofuel rated burners in the industry. Supported by a broad network of trained technicians, choosing a Beckett burner for your next commercial project ensures your building will have years of trouble-free operation while reducing your equipment’s impact on the environment. A return on investment for future generations.

Road Maintenance Solutions from Beckett®

When the sun is blazing and you're responsible for keeping Americas roads maintained, you'll want a burner that's as hard working as you are. Beckett's lineup of DC burners provides mobile heat for all types of road maintenance equipment. With their ease of service and parts availability from coast to coast, you can ensure the job gets done when the heat is on.

Heated Pressure Washing Solutions from Beckett®

For over 30 years Beckett has served the pressure washer market in providing rugged yet reliable burners and components for the pressure washer industry. Our compact DC powered burners provide off-grid dependable operation in the wettest of environments. All backed by a comprehensive warranty program that ensures you will have years of trouble-free operation. So, when the "pressure" is on to get a job done, you can rely on Beckett to keep you in "hot water".

Agriculture / Greenhouse Solutions from Beckett®

With a wide range of capacities, Beckett has served the needs of the agricultural industry for over 20 years. Our proven experience in the combustion field allows us to work with appliance engineers to ensure the strictest of parameters are met when drying organic products. Beckett's modular burner platform provides the most flexibility in applications while offering the most comprehensive lineup of biofuel rated burners in the industry. This ensures efficient reliable heat for future generations.

Construction Solutions from Beckett®

When freezing temperatures hit your job sites and you need dependable heat, consider Beckett for the job. From the Arctic circle to Antarctica, Beckett has proven to be the burner of choice in the harshest most remote environments. Our robust, user-friendly design provide quick maintenance and dependable operation to ensure your site stays warm.

Food Processing Solutions from Beckett®

Beckett burners and components are used in food processing applications all over the world. From bakery ovens, coffee roasters, dehydrators, and industrial process lines, Beckett robust, reliable products reduce line down time and ensure an uninterrupted output.

R.W. Beckett

From tank to flame, Beckett delivers the most technically advanced product line in the industry — burners, igniters, controls, and accessories designed to meet the performance requirements of the industry while meeting the demands of biofuels to reduce emissions and meet carbon reduction goals. Explore all that Beckett has to offer below by selecting a brand, product category, or simply filtering through the entire product offering.

Westwood by Beckett

With the acquisition of Westwood Products in 2021, Beckett added depth and diversity to its already impressive catalog. In addition to the Tigerloop suite of Oil Dearaetors which has been transitioned to our Beckett branded offering, our Westwood by Beckett product offering includes fuel filters, electrodes, tank accessories, and many other HVAC service and repair items. The line includes B100 filters which, in conjunction with the Tigerloop Bio models, completes Beckett’s industry leading suite of B100 rated components from tank-to-flame and further positions as the market leader in the drive to alternative fuels.

Residential Heating Solutions from Beckett®

For over 80 years Beckett products have been the number one choice of homeowners and contractors for their furnaces, boilers, and water heaters. As North America's foremost brand of burners, Beckett continues to provide industry leading design, reliability, and support. All backed by a comprehensive warranty program that ensures you will have years of trouble-free operation.

Commercial Heating/Steam Solutions from Beckett®

As North America's leading brand of burners, you can have peace of mind in using a Beckett burner on your next commercial project. With the environment in mind, we have the most comprehensive lineup of biofuel rated burners in the industry. Supported by a broad network of trained technicians, choosing a Beckett burner for your next commercial project ensures your building will have years of trouble-free operation while reducing your equipment’s impact on the environment. A return on investment for future generations.

Road Maintenance Solutions from Beckett®

When the sun is blazing and you're responsible for keeping Americas roads maintained, you'll want a burner that's as hard working as you are. Beckett's lineup of DC burners provides mobile heat for all types of road maintenance equipment. With their ease of service and parts availability from coast to coast, you can ensure the job gets done when the heat is on.

Heated Pressure Washing Solutions from Beckett®

For over 30 years Beckett has served the pressure washer market in providing rugged yet reliable burners and components for the pressure washer industry. Our compact DC powered burners provide off-grid dependable operation in the wettest of environments. All backed by a comprehensive warranty program that ensures you will have years of trouble-free operation. So, when the "pressure" is on to get a job done, you can rely on Beckett to keep you in "hot water".

Agriculture / Greenhouse Solutions from Beckett®

With a wide range of capacities, Beckett has served the needs of the agricultural industry for over 20 years. Our proven experience in the combustion field allows us to work with appliance engineers to ensure the strictest of parameters are met when drying organic products. Beckett's modular burner platform provides the most flexibility in applications while offering the most comprehensive lineup of biofuel rated burners in the industry. This ensures efficient reliable heat for future generations.

Construction Solutions from Beckett®

When freezing temperatures hit your job sites and you need dependable heat, consider Beckett for the job. From the Arctic circle to Antarctica, Beckett has proven to be the burner of choice in the harshest most remote environments. Our robust, user-friendly design provide quick maintenance and dependable operation to ensure your site stays warm.

Food Processing Solutions from Beckett®

Beckett burners and components are used in food processing applications all over the world. From bakery ovens, coffee roasters, dehydrators, and industrial process lines, Beckett robust, reliable products reduce line down time and ensure an uninterrupted output.

Beckett Oil Burners

R.W. Beckett oil-fired burners were created with customer satisfaction and sustainability in mind. Our utilization of advanced components results in higher efficiency and reliability, all while reducing carbon emissions.

Our burners are suitable for a multitude of needs. They are certified for firing traditional heating oils, biodiesel blends (B20), and renewable diesel blends (R95). Truly versatile, our burners are available in AC and DC voltages and in capacities from 0.40 to 35.0 GPH. Applicable uses range from residential homes to commercial buildings, for both industrial and process installations, R.W. Beckett can meet your demands. After installation our proven burners provide years of reliable service with strong and accessible technical support.

Beckett Gas Burners

R.W. Beckett gas-fired burners were created with customer satisfaction and sustainability in mind. Our utilization of advanced components results in higher efficiency, reliability, and accessibility, all while reducing carbon emissions.

Available in capacities ranging from 250 to 5,000 MBH, our burners are suitable for a multitude of needs. Applicable uses range from residential homes to commercial, for both industrial and process installations, R.W. Beckett can meet your demands. Our burners are easy to install and service, engineered to provide years of reliable service, and backed by solid technical support and fast delivery.

Beckett GeniSys® Burner Primary Safety Controls

R.W. Beckett’s burner controls were created with customer satisfaction and safety in mind. Our entire suite of burner controls utilizes the most current technology to safely control the combustion process.

Available in both AC and DC voltages for off-grid applications, our controls are suitable for a multitude of needs. Our new GeniSys® model 7565 Advanced Burner Control is compatible with the myTechnician™ app for modernized accessibility. The app assists with diagnostics, troubleshooting, and more. With applicable uses of our controls ranging from residential homes to commercial buildings, to process applications R.W. Beckett can meet your demands. Our multitude of models offer both fixed and programmable options and serve as a direct replacement for many competitive combustion controls.

Beckett AquaSmart® Boiler Safety Controls

R.W. Beckett’s boiler controls were created with customer satisfaction and sustainability in mind. The boiler control was built using Beckett’s proprietary HeatManager® algorithm which saves fuel by minimizing operating temperature, reducing energy consumption without sacrificing homeowner comfort.

Applicable to both oil and gas-fired boilers, the control is convenient for any household. With our digital display and touch pad we have made for a more intuitive experience, allowing for flexible programming of temperature limits and other settings.

Beckett Powerlight® Igniters

R.W. Beckett igniters were created with customer satisfaction and reliability in mind. Providing an advanced option for oil-fired burners, our Powerlight® igniter also serves as a universal replacement for other manufacturers’ igniters.

Available in a variety of AC and DC voltages for off-grid applications, our product is suitable for a multitude of needs. Designed for various applications, our igniter can be found in residential homes, commercial property, and even high-moisture environments.

PowerLight Gas Igniters

PowerLight Gas Igniters

Beckett's PowerLight® 120 VAC gas Igniters offer improved performance and longer life. This igniter is easy to install and is designed as a ...
Beckett Tigerloop® Oil Deaerators

R.W. Beckett’s oil deaerators were created with customer satisfaction and efficiency in mind. With over 30 years of fine-tuning, the Tigerloop® is the most advanced oil deaerator in the world.

With its unmatched performance, Tigerloop® can handle capacities up to 50 GPH and is compatible with different heating fuels, depending on the model. The standard model is compatible with #1 and #2 heating oil and B5 Bioheat, while the Bio model accepts biofuel blends up to B100. Catering to many needs, our oil deaerator is also a safe, economical, and environmentally friendly choice for all supply systems.

Beckett Oil Filters

Beckett branded Spin-on filters are epoxy coated, UL Listed or UL Recognized and rated from 10 to 15 microns. Commercial Spin-on filters are rated for 52 GPH, 20 PSI, and 30 Microns. The line includes a cast aluminum tops, Filter Life Indicator (FLi™) gauge and is suitable for #1 and #2 fuel oil and rated up to B100 bio-fuels.

Westwood by Beckett canister filters feature cast iron tops and epoxy coated canisters. Element options include Classic Felt, cellulose acetate, and Classic Yarn. UL Listed/Recognized canister filters exceed GPH and pressure ratings of most competitors.

Beckett Connected Devices

R.W Beckett’s internet connected products were created with customer satisfaction and accessibility in mind. With our modernized approach, these products can be remotely accessed through our mobile app or web browser.

Through the myTechnician™ mobile app, connected products come with multiple features including troubleshooting, product programming and diagnostics. With the BeckettLink® connected tank gauge system and Wi-Fi hub, end users and oil dealers can use the Beckett Dealer Dashboard to be alerted remotely if the tank drops below predetermined levels.

For your convenience, Tank Accessories has been divided into distinct categories to help you find the products you need. Please click the links below to see all the products in each of these categories.

Beckett Electrodes and Insulators

RW Beckett manufacturers hundreds of Westwood electrodes, flame rods and spark ignitors. Many are sold through distribution and additional items are available for OEM customers for special applications. RW Beckett can manufacture specialty electrodes to your specifications. The Auburn and Champion brands are also available.

All Categories

View All Products

Burner Settings

(OEM Spec Guides)

Specifications for nozzles, air tube combinations, and other initial settings.

Residential Oil Specifications Guide

Commercial Oil Specifications Guide

Residential Gas Specifications Guide

Commercial Gas Specifications Guide

Residential Oil Burner Specification Guide

Commercial Oil Burner Specification Guide

Appliance Mfg Appliance Boiler Burner Model Chassis Part No. Air Tube Combo High Fire Rate Nozzle Head Setting Low Fire Air or Shutter High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion Depth Note
Bryan Steam Corp. DR-250 CF375 BCF3907 CF56KZ 1.79 1.50 X 60°ES 1 10.00 0.50 N/A 140 51311 5.00" -
Bryan Steam Corp. DR-350 CF375 BCF3907 C100KZ 2.50 2.00 X 60°P 3 10.00 2.00 N/A 190 51311 5.00" -
Bryan Steam Corp. DR-450 CF500 BCF809 CF100KK 3.21 2.50 X 45°P 4 4.00 0.00 N/A 150 51311 5.00" -
Bryan Steam Corp. DR-650 CF800 BCF403 CF100KH 4.64 4.00 x 60°B (D) 3 7.00 0.00 N/A 140 51311 5.50" -
Bryan Steam Corp. DR-850 CF800 BCF403 CF100KJ 6.07 5.00 x 45°B (D) 2 8.00 8.00 N/A 150 51311 5.50" -
Buderus G215-3 AFG B2007 AFG50ML 1.10 0.90 X 45°ES 0 8.00 1.00 N/A 170 51311 3.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G215-4 AFG B2007 AFG50ML 1.40 1.10 X 45°ES 2 8.00 2.00 N/A 175 51311 3.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G215-5 CF375 BCF3907 CF56KY 1.75 1.35 X 45°ES 2 5.00 1.00 N/A 170 51311 3.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G215-6 CF375 BCF3907 CF56KZ 2.10 1.75 X 45°ES 1 7.00 2.00 N/A 140 51311 3.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G215-7 CF375 BCF3907 CF56KZ 2.50 2.00 X 45°P 1 9.00 3.00 N/A 150 51311 3.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G315-5 CF500 BCF809 CF80KK 3.00 2.50 X 45°P 3 7.00 0.00 N/A 140 51311 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G315-6 CF800 BCF403 CF80KH 3.85 3.25 X 45°P 1 7.00 0.00 N/A 140 51311 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G315-7 CF800 BCF403 CF80KH 4.70 4.00 X 45°P 2 10.00 0.00 N/A 140 51311 4.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G315-8 CF1400 BCF205 CF66KD 5.50 3.25 X 45°P 1 20.00 35.00 150 275 51312 4.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G315-9 CF1400 BCF205 CF66KD 6.40 3.75 X 45°P 3 25.00 40.00 150 275 51312 4.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G515-10 CF2300A BCF304 CF102KG 11.60 6.50 X 45°P 2 25.00 40.00 150 300 51312 6.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G515-11 CF2300A BCF304 CF102KG 13.00 7.50 X 45°P 6 25.00 40.00 150 300 51312 6.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G515-12 CF2300A BCF304 CF102KG 14.60 8.50 X 45°P 8 30.00 70.00 150 300 51312 6.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G515-7 CF1400 BCF205 CF102KD 6.90 4.00 X 60°P 5 20.00 30.00 150 300 51312 6.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G515-8 CF1400 BCF205 CF102KD 8.40 5.00 X 60°P 9 30.00 43.00 150 275 51312 6.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G515-9 CF2300A BCF304 CF102KG 10.00 5.50 X 45°P 0 20.00 33.00 150 300 51312 6.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G615-10 CF2500 BCF1801 CF102KP 18.50 5.00 x 45°P (2) 2 23.00 25.00 300 300 51630 6.25" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G615-11 CF2500 BCF1801 CF102KP 21.00 6.00 x 45°P (2) 5 27.00 40.00 300 300 51630 6.25" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G615-12 CF3500A BCF1301 CF114KM 23.50 6.50 x 45°P (2) 4 20.00 35.00 300 300 51630 6.25" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G615-13 CF3500A BCF1301 CF114KM 26.00 7.50 x 45°P (2) 5 25.00 40.00 300 300 51630 6.25" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G615-14 CF3500 BCF1301 CF114KR 28.50 8.50 x 60°P (2) 6 30.00 60.00 300 300 51631 6.25" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Buderus G615-9 CF2300A BCF304 CF102KG 16.00 9.00 X 45°P 5 30.00 60.00 150 300 51630 6.25" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler E20 CF800 BCF403 CF80KJ 6.00 5.00 x 60°SS 2 10.00 5.00 N/A 140 51628 5.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler E20 CF1400 BCF205 CF66KE 6.00 3.50 x 60°SS 0 20.00 40.00 125 300 51629 5.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler E30 CF1400 BCF205 CF66KE 9.00 5.00 x 60°SS 3 30.00 60.00 125 300 51629 5.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler E40 CF2300A BCF304 CF66KG 12.00 7.00 x 60°SS 1 30.00 40.00 125 300 51630 5.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler E50 CF2300A BCF304 CF66KG 15.00 9.00 x 60°SS 4 25.00 30.00 125 300 51630 5.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler E60 CF2300A BCF304 CF66KG 18.00 11.00 x 60°SS 6 35.00 90.00 125 300 51630 5.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FD-10 CF500 BCF809 CF60KK 3.00 2.50 X 45°P 2 4.00 0.00 N/A 150 51311 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FD-12 CF800 BCF403 CF60KH 4.00 3.25 X 45°P 1 5.50 0.00 N/A 150 51311 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FD-14 CF800 BCF403 CF60KH 4.50 3.75 X 45°P 2 7.00 0.00 N/A 150 51311 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FD-15 CF800 BCF403 CF60KH 5.00 4.00 X 45°P 2 8.00 0.00 N/A 150 51311 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FD-19 CF800 BCF403 CF60KH 6.00 4.50 x 60°B 4 10.00 2.00 N/A 150 51628 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FD-24 CF1400 BCF205 CF66KD 7.50 4.50 X 45°P 3 30.00 55.00 150 300 51629 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FD-30 CF1400 BCF205 CF66KE 9.50 5.50 X 45°P 1 30.00 75.00 150 300 51629 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FD-38 CF2300A BCF304 CF66KG 12.00 7.00 X 45°P 1 25.00 45.00 150 300 51313 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FD-45 CF2300A BCF304 CF66KG 13.80 8.00 X 45°P 1 25.00 60.00 150 300 51313 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FD-9 CF500 BCF809 CF60KK 2.75 2.00 X 45°P 2 4.00 0.00 N/A 150 51311 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FDO-10 CF500 BCF809 CF60KK 3.00 2.75 X 45°P 2 4.00 0.00 N/A 140 51311 4.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FDO-12 CF800 BCF403 CF60KH 4.00 3.50 X 45°P 2 6.00 0.00 N/A 140 51311 4.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FDO-14 CF800 BCF403 CF60KH 4.50 4.00 X 45°P 2 7.00 0.00 N/A 140 51311 4.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FDO-15 CF800 BCF403 CF60KH 5.00 4.50 X 45°P 2 8.00 0.00 N/A 140 51311 4.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FDO-19 CF800 BCF403 CF60KJ 6.00 5.00 X 45°P 3 10.00 3.00 N/A 140 51628 4.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FDO-24 CF1400 BCF205 CF66KD 7.50 4.50 X 45°P 3 30.00 55.00 150 300 51629 4.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FDO-30 CF1400 BCF205 CF66KE 9.00 5.50 X 45°P 1 45.00 75.00 150 300 51629 4.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FDO-38 CF2300A BCF304 CF66KG 12.00 7.00 X 45°P 1 25.00 45.00 150 300 51313 4.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FDO-45 CF2300A BCF304 CF66KG 13.80 8.00 X 45°P 1 25.00 60.00 150 300 51313 4.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FDO-7 CF500 BCF809 CF60KK 2.25 2.00 X 45°P 1 3.50 0.00 N/A 140 51311 4.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler FDO-9 CF500 BCF809 CF60KK 2.75 2.25 X 45°P 2 4.00 0.00 N/A 140 51311 4.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler MPC- 6 CF1400 BCF205 CF66KD 7.10 04.25 x 60°B D 4 43.00 48.00 150 250 0 4.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler MPC-10 CF2300A BCF304 CG66KG 13.40 08.00 x 45°B D 9 43.00 54.00 150 280 0 4.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler MPC-11 CF2500A BCF3001 CF66KP 15.00 04.50 x 45°P H 0 22.00 35.00 275 275 0 4.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler MPC-12 CF2500A BCF3001 CF66KP 16.60 05.00 x 45°P H 2 23.00 41.00 300 300 0 4.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler MPC-13 CF2500A BCF3001 CF66KP 18.20 05.50 x 45°P H 5 24.00 38.00 300 300 0 4.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler MPC-14 CF2500A BCF3001 CF66KP 19.20 06.00 x 45°P D 6 26.00 43.00 275 275 0 4.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler MPC-15 CF2500 BCF1801 CF66KP 21.50 06.50 x 45°P H 9 25.00 40.00 275 275 0 4.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler MPC-16 CF3500A BCF1301 CF144KR 23.00 07.00 x 45°P H 7 29.00 42.00 275 275 0 5.125" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler MPC-17 CF3500A BCF1301 CF114KR 24.50 07.50 x 45°P H 8 30.00 51.00 275 300 0 5.125" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler MPC-18 CF3500A BCF1301 CF114KR 26.00 07.00 x 45°P H 7 29.00 42.00 275 275 0 5.125" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler MPC-4 CF500 BCF809 CF66KK 3.55 02.75 x 70°B D 3 10.00 2.00 N/A 150 0 4.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler MPC-5 CF800 BCF403 CF60KH 5.50 04.50 x 70°B D 3 8.50 0.00 N/A 150 0 4.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler MPC-7 CF1400 BCB8302 CF66KE 7.80 05.00 x 45°B D 6 45.00 51.00 150 300 0 4.25' Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler MPC-8 CF2300A BCF304 CF66KG 10.20 06.00 x 45°B D 1 37.00 47.00 150 300 0 4.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler MPC-9 CF2500A BCF304 CF66KG 11.20 07.00 x 45°B D 7 39.00 47.00 150 300 0 4.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler PF-504 CF800 BCF403 CF60KH 5.45 4.50 X 45°P 2 5.00 10.00 N/A 140 51628 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler PF-505 CF1400 BCF205 CF66KD 6.80 3.50 X 45°P 3 25.00 50.00 150 300 51629 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler PF-506 CF1400 BCF205 CF66KD 8.30 4.50 X 45°P 4 30.00 60.00 150 300 51629 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler PF-507 CF1400 BCF205 CF66KD 9.80 5.50 X 45°P 5 35.00 70.00 150 300 51629 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler PF-508 CF2300A BCF304 CF66KG 11.20 6.00 X 45°P 2 20.00 70.00 150 300 51630 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler PF-509 CF2300A BCF304 CF66KG 12.60 7.00 X 45°P 2 20.00 85.00 150 300 51630 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler PF-510 CF2300A BCF304 CF66KG 14.00 8.00 X 45°P 3 25.00 95.00 150 300 51630 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler PF-511 CF2300A BCF304 CF66KG 15.50 8.50 X 45°P 4 25.00 100.00 150 300 51630 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler PF-512 CF2300A BCF304 CF66KG 17.00 9.50 X 45°P 4 30.00 105.00 150 300 51630 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler PF-513 CF2500A BCF1801 CF66KP 18.40 5.00 x 60°P (2) 3 23.00 35.00 300 300 51630 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler PF-514 CF2500A BCF1801 CF66KP 19.50 5.50 x 60°P (2) 4 25.00 40.00 300 300 51630 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler PF-515 CF2500 BCF1801 CF66KP 21.00 6.00 x 60°P (2) 4 25.00 50.00 300 300 51630 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler PF-516 CF2500 BCF1801 CF66KP 22.50 6.50 x 60°P (2) 5 25.00 50.00 300 300 51630 3.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler PF-517 CF3500A BCF1301 CF80KM 24.00 7.00 x 60°PLP (2) 2 30.00 80.00 300 300 51630 4.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler PF-518 CF3500A BCF1301 CF80KM 25.50 7.50 x 60°PLP (2) 3 32.00 95.00 280 280 51630 4.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler PF-519 CF3500A BCF1301 CF80KM 27.00 7.50 x 60°PLP (2) 3 35.00 105.00 300 300 51630 4.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler PF-520 CF3500A BCF1301 CF114KR 28.50 8.00 x 60°P (2) 4 37.00 95.00 300 300 51631 5.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler PF-521 CF3500A BCF1301 CF114KR 29.90 8.50 x 60°P (2) 4 40.00 103.00 300 300 51631 5.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V1104 CF1400 BCF205 CF66KD 5.80 3.50 X 45°P 0 25.00 50.00 150 300 51629 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V1105 CF1400 BCF205 CF66KE 7.40 4.50 X 45°P 0 30.00 50.00 150 300 51629 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V1106 CF1400 BCF205 CF66KE 9.20 5.50 X 45°P 2 30.00 60.00 150 300 51629 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V1107 CF2300A BCF304 CF66KG 11.00 6.50 X 45°P 2 30.00 60.00 150 300 51630 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V1108 CF2300A BCF304 CF66KG 13.00 7.50 X 45°P 4 35.00 60.00 150 300 51630 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V1109 CF2300A BCF304 CF66KG 14.80 8.50 X 45°P 4 35.00 75.00 150 300 51630 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V1110 CF2300A BCF304 CF66KS 16.60 9.50 X 45°P 4 30.00 55.00 150 300 51630 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V1111 CF2300A BCF304 CF66KS 18.40 10.50 X 45°P 6 40.00 60.00 150 300 51630 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V1112 CF2500A BCF1801 CF66KP 20.00 5.50 x 45°P (2) 4 20.00 45.00 300 300 51630 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V1113 CF2500A BCF1801 CF66KP 21.50 6.00 x 45°P (2) 5 22.00 55.00 300 300 51630 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V1114 CF3500 BCF1301 CF80KM 23.50 6.50 x 45°P (2) 2 25.00 80.00 300 300 51630 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V1115 CF3500A BCF1301 CF80KM 25.50 7.00 x 45°P (2) 3 30.00 90.00 300 300 51630 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V1116 CF3500A BCF1301 CF114KR 27.00 7.50 x 45°P (2) 6 32.00 85.00 300 300 51631 5.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-903 CF500 BCF809 CF80KK 2.75 2.25 X 60°P 2 10.00 5.50 N/A 140 51628 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-903A CF500 BCF809 CF60KK 3.10 2.50 X 45°P 2 10.00 3.00 N/A 150 51628 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-904 CF500 BCF809 CF80KK 3.50 3.00 X 45°P 3 10.00 5.50 N/A 140 51628 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-904A CF800 BCF403 CF80KH 4.20 3.50 X 45°P 1 8.00 0.00 N/A 150 51628 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-905 CF800 BCF403 CF80KH 4.60 4.00 X 60°P 4 10.00 5.00 N/A 140 51628 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-905A CF800 BCF403 CF80KH 5.60 4.50 X 45°P 2 10.00 6.00 N/A 150 51628 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-906 CF800 BCF403 CF80KJ 5.80 5.00 X 60°P 3 10.00 6.00 N/A 140 51628 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-906A CF1400 BCF205 CF66KD 7.00 4.00 X 60°P 3 28.00 40.00 150 300 51629 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-907 CF1400 BCF205 CF66KD 6.90 4.00 X 45°P 3 35.00 60.00 125 300 51629 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-907A CF1400 BCF205 CF66KD 8.30 5.00 X 45°P 4 30.00 65.00 150 275 51629 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-908 CF1400 BCF205 CF66KE 8.00 4.50 X 45°P 3 25.00 50.00 125 300 51629 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-908A CF1400 BCF205 CF66KEE 9.60 5.50 X 45°P 1 35.00 85.00 150 300 51629 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-909 CF1400 BCF205 CF66KE 9.10 5.00 X 45°P 3 30.00 55.00 125 300 51629 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-909A CF2300A BCF304 CF66KG 11.60 7.00 X 45°P 0 20.00 40.00 150 275 51630 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-910 CF1400 BCF205 CF66KE 10.20 5.50 X 45°P 5 40.00 75.00 125 300 51629 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-910A CF2300A BCF304 CF66KG 13.20 8.00 X 45°P 1 20.00 60.00 150 275 51630 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-911 CF2300A BCF304 CF66KG 11.40 6.50 X 45°P 1 38.00 45.00 125 300 51630 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-911A CF2500A BCF1801 CF66KP 14.80 4.50 x 45°P (2) 0 17.00 30.00 275 275 51630 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-912 CF2300A BCF304 CF66KG 12.60 7.00 X 45°P 4 40.00 50.00 125 300 51630 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Burnham / US Boiler V-912A CF2500A BCF1801 CF66KP 16.40 5.00 x 45°P (2) 0 20.00 40.00 275 275 51630 4.12" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. CT-20 CF800 BCF403 CF100KJ 6.00 5.00 X 60°P 3 7.00 0.00 N/A 150 51628 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. CT-25 CF1400 BCF205 CF66KD 9.00 5.50 X 60°P 3 30.00 50.00 150 300 51629 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. CT-25 CF1000 BCF101 CF66KD 7.50 4.50 X 60°P 3 5.00 0.00 N/A 275 51629 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. CT-35 CF2300A BCF304 CF66KG 10.50 6.00 X 45°P 3 30.00 50.00 150 300 51630 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. CT-50 CF2300A BCF304 CF66KG 15.00 9.00 X 60°P 3 30.00 50.00 150 300 51630 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. CWH-1200 CF1400 BCF205 CF66KD 9.00 5.50 X 60°P 3 30.00 50.00 150 300 51629 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. CWH-1200 CF1000 BCF101 CF66KD 9.00 5.50 X 60°P 3 5.00 0.00 N/A 275 51629 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. CWH-1510 CF2300A BCF304 CF66KG 12.00 7.00 x 45°SS 3 30.00 50.00 150 300 51630 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. CWH-1810 CF2300A BCF304 CF66KG 14.00 8.00 X 60°P 3 30.00 50.00 150 300 51630 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. CWH-2460 CF2300A BCF304 CF66KG 18.00 10.00 X 60°P 3 30.00 50.00 150 300 51630 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. CWH-780 CF800 BCF403 CF100KJ 6.00 5.00 X 60°P 3 7.00 0.00 N/A 150 51628 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. HRT-20 CF800 BCF403 CF100KJ 6.00 5.00 X 60°P 3 7.00 0.00 N/A 150 51628 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. HRT-30 CF1000 BCF101 CF66KD 9.00 5.50 X 60°P 3 5.00 0.00 N/A 275 51629 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. HRT-30 CF1400 BCF205 CF66KD 9.00 5.50 X 60°P 3 30.00 50.00 150 300 51629 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. HRT-40 CF1400 BCF205 CF66KE 12.00 7.00 X 60°P 3 30.00 50.00 150 300 51629 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. HRT-50 CF2300A BCF304 CF66KG 15.00 10.00 X 60°P 3 30.00 50.00 125 225 51630 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. HRT-60 CF2300A BCF304 CF66KG 18.00 10.00 X 60°P 3 30.00 50.00 150 300 51630 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. WL-120 CF2300A BCF304 CF66KG 12.00 7.00 x 45°SS 3 30.00 50.00 150 300 51630 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. WL-140 CF2300A BCF304 CF66KG 14.00 8.00 X 60°P 3 30.00 50.00 150 300 51630 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. WL-180 CF2300A BCF304 CF66KG 18.00 10.00 X 60°P 3 30.00 50.00 150 300 51630 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. WL-60 CF800 BCF403 CF100KJ 6.00 5.00 X 60°P 3 7.00 0.00 N/A 150 51628 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. WL-90 CF1000 BCF101 CF66KD 9.00 5.50 X 60°P 3 5.00 0.00 N/A 275 51629 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Columbia Boiler Co. WL-90 CF1400 BCF205 CF66KD 9.00 5.50 X 60°P 3 30.00 50.00 150 300 51629 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. CT6 SMG B1403 SMG45NR 1.65 1.35 X 45°ES 0 7.00 1.00 N/A 150 51311 1.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. CT6 CF375 BCF3907 CF56KY 1.65 1.35 X 60°ES 1 6.00 0.00 N/A 150 51311 1.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. CT7 CF500 BCF809 CF60KK 2.00 1.75 X 60°ES 1 3.50 0.00 N/A 140 51311 2.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. CT8 CF500 BCF809 CF60KK 2.50 2.00 X 45°B 2 4.50 0.00 N/A 140 51311 2.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. F4 CF800 BCF403 CF80KHS 3.00 2.50 X 60°B 0 4.00 0.00 N/A 140 51311 7.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. F5 CF800 BCF403 CF80KHS 4.00 3.25 X 45°P 1 5.00 0.00 N/A 140 51311 7.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. F6 CF800 BCF403 CF80KHS 5.00 4.00 X 45°P 3 7.00 0.00 N/A 140 51311 7.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. F7 CF1400 BCF205 CF102KD 6.00 3.50 X 45°P 2 25.00 38.00 125 275 51312 7.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. F8 CF1400 BCF205 CF102KD 7.50 4.50 X 45°P 4 35.00 60.00 125 275 51312 7.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. F9 CF2300A BCF304 CF102KG 9.00 5.00 X 45°P 0 20.00 33.00 150 275 51630 7.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. FW4 CF500 BCF809 CF80KK 3.00 2.50 X 60°B 2 4.50 0.00 N/A 140 51311 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. FW5 CF800 BCF403 CF80KHS 4.00 3.25 X 45°P 1 5.00 0.00 N/A 140 51311 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. FW6 CF800 BCF403 CF80KHS 5.00 4.00 X 45°P 3 7.00 0.00 N/A 140 51311 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. FW7 CF1400 BCF205 CF102KE 6.00 3.50 X 45°P 2 25.00 38.00 125 275 51312 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. FW8 CF1400 BCF205 CF102KE 7.50 4.50 X 45°B 4 35.00 60.00 125 275 51312 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. FW9 CF2300A BCF304 CF102KG 9.00 5.50 X 45°P 0 20.00 33.00 150 275 51313 4.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. VH10 CF2300A BCF304 CF66KG 14.00 8.00 X 45°P 1 20.00 50.00 125 300 51630 5.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. VH11 CF2300A BCF304 CF66KG 15.80 9.00 X 45°P 2 30.00 60.00 125 300 51630 5.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. VH12 CF2300A BCF304 CF66KG 17.60 10.00 X 45°P 3 40.00 70.00 125 300 51630 5.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. VH13 CF2500A BCF3001 CF66KP 19.60 5.00 x 45°P (2) 1 20.00 40.00 300 300 51630 5.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. VH14 CF2500 BCF1801 CF66KP 21.50 6.00 x 45°P (2) 2 20.00 40.00 300 300 51630 5.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. VH15 CF2500 BCF1801 CF66KP 23.50 6.50 x 45°P (2) 4 20.00 40.00 300 300 51630 5.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. VH16 CF3500A BCF1301 CF80KM 25.00 7.50 x 45°P (2) 7 30.00 70.00 300 300 51630 5.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. VH17 CF3500A BCF1301 CF80KM 27.00 8.00 x 45°P (2) 7 30.00 60.00 300 300 51630 5.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. VH8 CF2300A BCF304 CF66KG 10.20 6.00 X 45°P 0 16.00 30.00 125 300 51630 5.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Crown Boiler Co. VH9 CF2300A BCF304 CF66KG 12.00 7.00 X 45°P 0 20.00 40.00 125 300 51630 5.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Dedietrich / Marketing Company of North America GT214A AFG B2007 AFG50MLSS 1.20 1.00 X 60°B 1 10.00 1.00 N/A 150 51311 4.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Dedietrich / Marketing Company of North America GT215A AFG B2007 AFG50MLSS 1.55 1.25 X 45°B 2 10.00 3.00 N/A 150 51311 4.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Dedietrich / Marketing Company of North America GT216A CF375 BCF3907 CF56KY 1.90 1.35 X 45°ES 1 7.50 0.00 N/A 200 51311 4.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Dedietrich / Marketing Company of North America GT217A CF500 BCF809 CF60KK 2.25 1.75 X 45°B 2 4.00 0.00 N/A 150 51311 3.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Dedietrich / Marketing Company of North America GT218A CF500 BCF809 CF60KK 2.50 2.00 x 45°B (D) 2 5.00 0.00 N/A 150 51311 3.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Dedietrich / Marketing Company of North America GT304 CF500 BCF809 CF60KK 2.82 2.25 X 45°P 1 4.00 1.00 N/A 150 51628 5.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Dedietrich / Marketing Company of North America GT305 CF800 BCF403 CF80KH 4.10 3.50 X 45°P 1 6.50 0.00 N/A 140 51628 5.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Dedietrich / Marketing Company of North America GT306 CF800 BCF403 CF80KH 5.60 4.50 X 45°P 4 10.00 2.50 N/A 150 51628 5.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Dedietrich / Marketing Company of North America GT307 CF1400 BCF205 CF66KD 7.10 4.25 X 45°P 3 28.00 40.00 150 300 51312 5.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Dedietrich / Marketing Company of North America GT308 CF1400 BCF205 CF66KD 8.50 5.00 X 45°P 6 35.00 45.00 150 300 51312 5.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Dedietrich / Marketing Company of North America GT309 CF2300A BCF304 CF102KG 10.00 6.00 X 45°P 0 28.00 30.00 125 275 51313 5.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Dunkirk Boiler DPFO-6 CF375 BCF3907 CF56KZ 2.10 1.75 X 60°B(D) 2 10.00 0.00 N/A 140 51311 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Dunkirk Boiler DPFO-7 CF375 BCF3907 CF56KZ 2.35 2.00 x 60°B (D) 2 10.00 2.50 N/A 140 51311 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Dunkirk Boiler DPFO-8 CF375 BCF3907 CF56KZ 2.75 2.25 X 60°B (D) 3 10.00 3.00 N/A 140 51311 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Dunkirk Boiler DPFO-9 CF375 BCF3907 CF56KZ 3.33 3.00 x 45°B (D) 5 10.00 10.00 N/A 140 51311 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Dunkirk Boiler DPFO-9 CF375 BCF3907 CF56KZ 3.00 2.50 X 60°P 5 10.00 4.00 N/A 140 51311 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler ESP-100 CF3500 BCF1301 CF114KR 30.00 8.50 x 45°P (2) 7 35.00 95.00 300 300 51631 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler ESP-70 CF2500 BCF1801 CF102KP 21.00 6.00 x 45°P (2) 5 10.00 50.00 300 300 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler ESP-80 CF3500 BCF1301 CF80KM 24.00 6.50 x 45°P (2) 2 20.00 80.00 300 300 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler ESP-90 CF3500 BCF1301 CF114KR 27.00 7.50 x 45°P (2) 6 25.00 85.00 300 300 51631 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler FST-100 CF3500 BCF1301 CF114KR 30.00 8.50 x 45°P (2) 7 35.00 95.00 300 300 51631 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler FST-20 CF1400 BCF205 CF102KE 6.10 3.50 X 45°P 0 20.00 40.00 150 300 51629 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler FST-20 CF800 BCF403 CF100KH 6.00 4.50 X 45°P 3 10.00 3.00 N/A 150 51628 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler FST-32 CF1400 BCF205 CF102KE 9.60 5.50 X 45°P 4 35.00 70.00 150 300 51629 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler FST-40 CF2300A BCF304 CF102KG 12.00 6.50 X 45°P 1 17.00 30.00 150 300 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler FST-50 CF2300A BCF304 CF102KG 15.60 8.50 X 45°P 4 35.00 75.00 150 300 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler FST-60 CF2300A BCF304 CF102KG 18.00 10.00 X 45°P 5 30.00 60.00 150 300 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler FST-70 CF2500 BCF1801 CF102KP 21.00 6.00 x 45°P (2) 5 20.00 50.00 300 300 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler FST-80 CF3500 BCF1301 CF80KM 24.00 6.50 x 45°P (2) 2 20.00 80.00 300 300 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler FST-90 CF3500 BCF1301 CF114KR 27.00 7.50 x 45°P (2) 6 25.00 85.00 300 300 51631 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler PLW-53 CF2300A BCF304 CF102KG 16.00 9.50 X 45°P 5 30.00 60.00 150 275 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler PLW-60 CF2300A BCF304 CF102KG 18.00 10.00 X 45°P 7 35.00 70.00 150 300 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler PLW-66 CF2300A BCF304 CF102KS 19.90 11.00 X 45°P 9 50.00 100.00 150 300 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler PLW-79 CF3500 BCF1301 CF80KM 24.00 7.00 x 45°P (2) 7 35.00 85.00 275 275 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler PLW-93 CF3500 BCF1301 CF114KR 28.00 8.00 x 45°P (2) 8 45.00 95.00 300 300 51631 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM4-100 CF3500 BCF1301 CF114KR 30.00 8.50 x 45°P (2) 7 35.00 95.00 300 300 51631 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM4-20 CF800 BCF403 CF100KH 6.00 4.50 X 45°P 3 10.00 3.00 150 0 51628 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM4-32 CF1400 BCF205 CF102KE 9.60 5.50 X 45°P 4 35.00 70.00 150 300 51629 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM4-40 CF2300A BCF304 CF102KG 12.00 6.50 X 45°P 1 16.00 30.00 150 300 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM4-50 CF2300A BCF304 CF102KG 15.00 8.50 X 45°P 4 35.00 75.00 150 300 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM4-60 CF2300A BCF304 CF102KG 18.00 10.00 X 45°P 5 30.00 60.00 150 300 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM4-70 CF2500 BCF1801 CF102KP 21.00 6.00 x 45°P (2) 5 20.00 50.00 300 300 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM4-80 CF3500 BCF1301 CF80KM 24.00 6.50 x 45°P (2) 2 20.00 80.00 300 300 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM4-90 CF3500 BCF1301 CF114KR 27.00 7.50 x 45°P (2) 6 25.00 85.00 300 300 51631 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM5-100 CF3500 BCF1301 CF114KR 29.20 8.50 x 45°P (2) 8 50.00 100.00 280 280 51631 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM5-20 CF800 BCF403 CF100KH 5.80 4.50 X 45°P 3 10.00 3.00 150 0 51628 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM5-25 CF1000 BCF101 CF102KD 7.30 4.00 X 45°P 4 20.00 0.00 300 0 51629 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM5-30 CF1400 BCF205 CF102KE 8.70 5.00 X 45°P 7 20.00 40.00 150 300 51629 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM5-35 CF1400 BCF205 CF102KE 10.20 5.50 X 45°P 9 30.00 70.00 150 300 51629 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM5-40 CF2300A BCF304 CF102KG 11.70 7.00 X 45°P 0 16.00 30.00 150 275 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM5-50 CF2300A BCF304 CF102KG 14.60 8.50 X 45°P 3 20.00 40.00 150 275 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM5-60 CF2300A BCF304 CF102KG 17.50 10.00 X 45°P 6 20.00 70.00 150 300 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM5-60S CF2300A BCF304 CF102KG 17.50 10.00 X 45°P 6 20.00 70.00 150 300 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM5-70 CF2500 BCF1801 CF102KP 20.40 6.00 x 45°P (2) 8 40.00 90.00 275 275 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM5-80 CF3500 BCF1301 CF80KM 23.30 6.50 x 45°P (2) 7 30.00 80.00 300 300 51630 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Easco Boiler SM5-90 CF3500 BCF1301 CF114KR 26.20 7.50 x 45°P (2) 7 40.00 90.00 300 300 51631 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Hurst Cyclone 10HP CF500 BCF809 CF100KK 3.50 3.00 x 60°B 3 10.00 2.00 N/A 140 51311 N/A Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Hurst Cyclone 15HP CF800 BCF403 CF140KH 4.50 4.00 X 60°B 4 10.00 3.00 N/A 140 51312 N/A Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Hurst Cyclone 20HP CF1400 BCF205 CF136KD 6.00 3.50 X 45°P 0 20.00 40.00 150 300 51312 N/A Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Hurst Cyclone 25HP CF1400 BCF205 CF136KD 7.50 4.50 X 45°P 3 35.00 60.00 150 300 51312 N/A Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Hurst Cyclone 30HP CF2300A BCF304 CF136KG 9.00 5.00 X 45°P 1 30.00 40.00 150 300 51313 N/A Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Hurst Cyclone 40HP CF2300A BCF304 CF136KG 12.00 7.00 X 45°P 2 30.00 60.00 150 300 51313 N/A Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Hurst Cyclone 50HP CF2300A BCF304 CF136KG 15.00 8.50 X 45°P 3 35.00 75.00 150 300 51313 N/A Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Hurst Cyclone 60HP CF2500 BCF1801 CF176KP 18.00 5.00 x 60°P (2) 3 19.00 40.00 300 300 51313 N/A Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Hurst Cyclone 6HP CF500 BCF809 CF100KK 2.00 1.75 X 60°B(D) 0 2.00 0.00 N/A 140 51311 N/A Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Hurst Cyclone 70HP CF2500 BCF1801 CF176KP 21.00 6.00 x 60°P (2) 4 26.00 50.00 300 300 51313 N/A Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Hurst Cyclone 80HP CF3500A BCF1301 CF150KM 24.00 7.00 x 60°P (2) 3 32.00 90.00 300 300 51630 N/A Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
National Combustion CO-XC 105 CF1400 BCF205 CF66KE 8.00 4.50 X 45°P 2 30.00 60.00 150 300 51629 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
National Combustion CO-XC 130 CF2300A BCF304 CF66KG 10.00 5.50 X 45°P 0 15.00 30.00 150 300 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
National Combustion CO-XC 165 CF2300A BCF304 CF66KG 12.00 7.00 X 45°P 1 30.00 40.00 150 300 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
National Combustion CO-XC 200 CF2300A BCF304 CF66KG 15.00 9.00 X 45°P 4 25.00 40.00 150 300 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
National Combustion CO-XC 250 CF2300A BCF304 CF102KS 19.00 11.00 X 45°P 5 35.00 55.00 150 300 51630 6.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
National Combustion CO-XC 290 CF2500A BCF1801 CF66KP 22.00 6.50 x 45°P (2) 5 25.00 50.00 300 300 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
National Combustion CO-XC 400 CF3500A BCF1301 CF114KR 29.90 8.50 x 45°P (2) 5 30.00 80.00 300 300 51631 6.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
National Combustion CO-XC 58 CF800 BCF403 CF60KH 4.50 4.00 X 45°P 3 10.00 0.00 N/A 140 51311 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
National Combustion CO-XC 72 CF800 BCF403 CF60KH 5.25 4.50 X 45°P 4 10.00 5.00 N/A 140 51311 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
National Combustion CO-XC 82 CF1400 BCF205 CF66KE 6.00 3.50 X 45°P 0 20.00 40.00 150 300 51629 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 704-FDA CF800 BCF403 CF60KH 3.95 3.50 x 70°B 0 40.00 10.00 N/A 140 51311 2.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 705-FDA CF800 BCF403 CF60KJ 5.10 4.50 x 60°B 1 40.00 10.00 N/A 140 51311 2.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 706-FDA CF800 BCF403 CF60KJ 6.20 5.00 x 60°B 3 60.00 10.00 N/A 140 51311 2.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 707-FDA CF1400 BCF205 CF66KD 7.40 4.50 X 45°B 3 35.00 60.00 150 300 51629 3.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 708-FDA CF1400 BCF205 CF66KD 8.50 5.00 X 45°B 4 50.00 75.00 150 300 51629 3.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 709-FDA CF1400 BCF205 CF66KD 9.60 5.50 x 45°B 5 50.00 80.00 150 300 51629 3.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 710-FDA CF2300A BCF304 CF66KG 10.80 6.00 X 45°P 0 15.00 30.00 150 300 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 711-FDA CF2300A BCF304 CF66KG 12.00 7.00 X 45°P 0 20.00 40.00 150 300 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 712-FDA CF2300A BCF304 CF66KG 13.00 7.50 X 45°P 1 25.00 45.00 150 300 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 713-FDA CF2300A BCF304 CF66KG 14.20 8.00 X 45°P 2 30.00 50.00 150 300 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 714-FDA CF2300A BCF304 CF66KG 15.40 9.00 X 45°P 2 30.00 60.00 150 300 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 715-FDA CF2300A BCF304 CF66KG 16.40 9.50 X 45°P 4 40.00 65.00 150 300 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 716-FDA CF2300 BCF304 CF66KG 17.60 10.00 X 45°P 6 35.00 85.00 150 300 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 717-FDA CF2500A BCF3001 CF66KP 18.80 5.50 x 45°P (2) 1 18.00 40.00 300 300 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 718-FDA CF2500A BCF3001 CF66KP 19.80 6.00 x 45°P (2) 2 22.00 60.00 275 275 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 719-FDA CF2500 BCF1801 CF66KP 21.00 6.00 x 45°P (2) 4 21.00 60.00 300 300 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 720-FDA CF2500 BCF1801 CF66KP 22.00 6.50 x 45°P (2) 6 30.00 60.00 285 285 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 721-FDA CF2500 BCF1801 CF66KP 23.50 7.00 x 45°P (2) 8 35.00 70.00 280 280 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 722-FDA CF3500A BCF1301 CF80KM 24.50 7.00 x 45°P (2) 4 20.00 40.00 300 300 51630 4.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 723-FDA CF3500A BCF1301 CF80KM 25.50 7.50 x 45°P (2) 5 22.00 50.00 290 290 51630 4.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler 724-FDA CF3500 BCF1301 CF80KM 26.50 8.00 x 45°P (2) 6 25.00 60.00 275 275 51630 4.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler EC-06 CF375 BCF3907 CF56KZ 3.00 2.50 X 45°P 3 10.00 7.00 N/A 140 51311 2.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler EC-06 CF375 BCF3907 CF56KZ 2.75 2.25 X 45°P 1 10.00 6.00 N/A 140 51311 2.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler JO-10FDA CF800 BCF403 CF60KH 6.00 5.00 x 60°B 5 10.00 6.00 N/A 140 51311 2.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler JO-6FDA CF800 BCF403 CF60KH 3.50 3.00 x 45°B 0 5.00 0.00 N/A 140 51311 2.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler JO-7FDA CF800 BCF403 CF60KH 4.00 3.50 x 60°B 1 8.00 0.00 N/A 140 51311 2.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler JO-8FDA CF800 BCF403 CF60KH 4.50 4.00 X 60°B 2 10.00 0.00 N/A 140 51311 2.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler JO-9FDA CF800 BCF403 CF60KH 5.00 4.50 x 60°B 4 10.00 2.00 N/A 140 51311 2.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LC04 CF800 BCF403 CF60KH 4.75 4.00 X 45°P 2 0.00 9.00 N/A 140 51311 2.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LC05 CF1400 BCF205 CF66KD 6.10 3.50 X 45°P 0 25.00 50.00 150 300 51629 3.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LC05R CF800 BCF403 CF60KH 5.60 4.50 X 45°P 2 0.00 10.00 N/A 140 51311 2.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LC06 CF1400 BCF205 CF66KD 7.50 4.50 X 45°P 1 25.00 60.00 150 280 51629 3.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LC07 CF1400 BCF205 CF66KD 8.80 5.00 X 45°P 5 35.00 80.00 150 300 51629 3.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LC08 CF2300A BCF304 CF66KG 10.20 6.00 X 45°P 0 20.00 35.00 150 280 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LC09 CF2300A BCF304 CF66KG 11.60 6.50 X 45°P 1 20.00 40.00 150 300 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LC10 CF2300A BCF304 CF66KG 12.80 7.00 X 45°P 2 25.00 50.00 150 300 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LC11 CF2300A BCF304 CF66KG 14.20 8.50 X 45°P 2 30.00 70.00 150 280 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LC12 CF2300 BCF304 CF66KG 15.60 9.00 X 45°P 3 35.00 90.00 150 300 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LCE-13 CF2300A BCF304 CF66KG 17.00 10.00 X 45°P 6 30.00 80.00 150 290 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LCE-14 CF2300A BCF304 CF66KS 18.40 11.00 X 45°P 3 30.00 60.00 150 280 51630 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LCE-15 CF2300 BCF304 CF66KS 19.80 12.00 X 45°P 3 30.00 100.00 150 275 51630 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LCE-16 CF2500 BCF1801 CF66KP 21.00 6.00 x 45°P (2) 4 20.00 60.00 300 300 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LCE-17 CF2500 BCF1801 CF66KP 22.50 6.50 x 45°P (2) 6 35.00 60.00 300 300 51630 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LCE-18 CF3500A BCF1301 CF66KM 24.00 7.00 x 45°P (2) 3 23.00 40.00 295 295 51630 4.250" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LCE-19 CF3500A BCF1301 CF66KM 25.00 7.50 x 45°P (2) 5 25.00 40.00 275 275 51630 4.250" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LCE-20 CF3500 BCF1301 CF66KM 26.50 8.00 x 45°P (2) 6 27.00 60.00 275 275 51630 4.250" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LCE-21 CF3500A BCF1301 CF114KR 28.00 8.00 x 45°P (2) 5 30.00 80.00 300 300 51631 5.125" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler LCE-22 CF3500A BCF1301 CF114KR 29.50 8.50 x 45°P (2) 5 35.00 85.00 300 300 51631 5.125" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler SC05 CF500 BCF809 CF60KK 3.00 2.50 X 60°B 2 7.00 1.00 N/A 140 51311 2.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler SC06 CF500 BCF809 CF60KK 3.50 3.00 x 60°B 3 10.00 10.00 N/A 140 51311 2.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler SC07 CF800 BCF403 CF60KH 4.00 3.25 X 45°P 1 6.00 0.00 N/A 150 51311 2.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler SC08 CF800 BCF403 CF60KH 4.50 3.75 X 45°P 2 7.00 1.00 N/A 140 51311 2.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler SC09 CF800 BCF403 CF60KH 5.00 4.00 X 30°P 3 7.00 2.00 N/A 150 51311 2.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler SC10 CF800 BCF403 CF60KH 5.50 4.50 X 30°P 4 10.00 4.00 N/A 150 51311 2.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler TC-04 CF1400 BCF205 CF66KE 8.00 5.00 X 45°P 2 40.00 70.00 150 300 51629 4.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler TC-05 CF1400 BCF205 CF66KE 10.40 6.00 X 45°P 4 40.00 90.00 150 300 51629 4.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler TC-06 CF2300A BCF304 CF66KG 12.60 7.50 X 45°P 1 20.00 40.00 150 300 51630 4.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler TC-07 CF2300A BCF304 CF66KG 15.00 9.00 X 45°P 3 30.00 55.00 150 300 51630 4.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler TC-08 CF2300 BCF304 CF66KG 17.40 10.00 X 45°P 5 30.00 60.00 150 300 51630 4.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler TC-09 CF2300A BCF304 CF66KS 19.60 11.00 X 45°P 3 30.00 70.00 150 300 51630 4.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler TC-10 CF2500 BCF1801 CF66KP 22.00 6.50 X 45°P 6 18.00 40.00 300 300 51630 4.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler TC-11 CF2500 BCF1801 CF66KP 24.50 7.00 X 45°P 8 28.00 90.00 300 300 51630 4.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler TC-12 CF3500A BCF1301 CF80KM 26.50 8.00 X 45°P 7 32.00 90.00 300 300 51630 4.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler TC-13 CF3500A BCF1301 CF114KR 29.00 9.00 X 60°P 7 50.00 100.00 300 300 51631 5.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Slant / Fin LD-60 CF375 BCF3907 CF56KZ 2.85 2.25 X 45°P 2 10.00 2.00 N/A 160 51311 2.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Slant / Fin LD-60 CF375 BCF3907 CF56KZ 2.60 2.25 X 45°P 1 10.00 3.00 N/A 135 51311 2.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Slant / Fin LD-70 CF375 BCF3907 CF56KZ 3.35 2.75 X 60°B 5 10.00 4.00 N/A 148 51311 2.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Slant / Fin LD-70 CF375 BCF3907 CF56KZ 3.00 2.50 X 45°SS 3 10.00 4.00 N/A 145 51311 2.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Slant / Fin LD-70 CF375 BCF3907 CF56KZ 3.10 2.50 X 45°SS 4 10.00 4.00 N/A 155 51311 2.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 18-10 CF800 BCF403 CF60KJ 6.90 6.00 X 60°PLP 5 10.00 8.00 N/A 140 51628 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 18-10 CF1400 BCF205 CF66KD 6.90 4.00 X 45°PLP 3 25.00 60.00 125 300 51629 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 18-11 CF1000 BCF101 CF66KE 7.60 4.50 X 45°PLP 4 20.00 0.00 N/A 300 51629 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 18-11 CF1400 BCF205 CF66KD 7.60 4.50 X 45°PLP 4 30.00 60.00 125 300 51629 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 18-12 CF1400 BCF205 CF66KD 8.30 5.00 X 45°PLP 5 25.00 70.00 125 300 51629 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 18-12 CF1000 BCF101 CF66KE 8.30 5.00 X 45°PLP 4 21.00 0.00 N/A 300 51629 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 18-4 CF500 BCF809 CF60KK 2.55 2.25 X 60°PLP 1 4.00 0.00 N/A 140 51628 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 18-5 CF500 BCF809 CF60KK 3.25 2.75 X 60°PLP 3 5.00 0.00 N/A 140 51628 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 18-6 CF500 BCF809 CF60KK 4.00 3.50 X 60°PLP 5 10.00 4.00 N/A 140 51628 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 18-7 CF800 BCF403 CF60KJ 4.70 4.00 X 60°PLP 1 7.00 0.00 N/A 140 51628 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 18-7 CF500 BCF809 CF60KK 4.70 4.00 X 60°PLP 6 10.00 10.00 N/A 140 51628 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 18-8 CF800 BCF403 CF60KJ 5.40 4.50 X 60°PLP 2 10.00 0.00 N/A 140 51628 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 18-9 CF800 BCF403 CF60KJ 6.10 5.00 X 60°PLP 4 10.00 3.00 N/A 140 51628 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19-10 CF1400 BCF205 CF66KE 9.50 5.50 X 45°PLP 4 40.00 70.00 125 300 51629 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19-11 CF1400 BCF205 CF66KE 10.40 6.00 X 45°PLP 5 40.00 80.00 125 300 51629 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19-12 CF2300A BCF304 CF66KG 11.40 6.50 X 45°PLP 1 16.00 30.00 125 300 51630 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19-3 CF500 BCF809 CF80KK 2.60 1.75 X 60°ES 2 4.00 0.00 N/A 180 51628 1.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19-4 CF500 BCF809 CF80KK 3.60 3.00 x 45°B 5 8.00 0.00 N/A 140 51628 1.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19-5 CF800 BCF403 CF80KH 4.60 4.00 X 60°PLP 3 10.00 5.00 N/A 140 51628 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19-6 CF800 BCF403 CF80KH 5.60 4.50 X 60°PLP 4 10.00 8.00 N/A 140 51628 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19-7 CF1400 BCF205 CF66KD 6.50 4.00 X 45°PLP 3 30.00 60.00 125 275 51629 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19-8 CF1400 BCF205 CF66KE 7.50 4.50 X 45°PLP 2 30.00 50.00 125 275 51629 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19-9 CF1400 BCF205 CF66KE 8.50 5.00 X 45°PLP 3 35.00 60.00 125 300 51629 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19A-10 CF2300A BCF304 CF66KG 12.10 7.00 X 45°P 0 25.00 33.00 175 275 51630 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19A-11 CF2500 BCF1801 CF102KP 13.50 5.00 X 45°B 0 18.00 25.00 300 300 51630 4.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19A-12 CF2500 BCF1801 CF102KP 15.00 5.50 X 45°P 0 20.00 30.00 300 300 51630 4.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19A-3 CF500 BCF809 CF80KK 2.60 1.75 X 60°ES 2 4.00 0.00 N/A 180 51628 1.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19A-4 CF500 BCF809 CF80KK 3.60 3.00 x 45°B 5 8.00 0.00 N/A 140 51628 1.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19A-5 CF800 BCF403 CF60KH 5.00 4.00 X 45°B 2 10.00 4.00 N/A 150 51628 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19A-6 CF1400 BCF205 CF66KD 6.40 4.00 X 45°P 2 28.00 40.00 150 250 51629 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19A-7 CF1400 BCF205 CF66KD 7.80 4.50 X 45°P 3 35.00 60.00 150 300 51629 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19A-8 CF2300A BCF304 CF66KF 9.30 5.50 x 60°B (D) 3 15.00 43.00 125 275 51630 3.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 19A-9 CF2300A BCF304 CF66KG 10.70 6.50 X 45°P 0 23.00 28.00 175 275 51630 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 28-10 CF2500 BCF1801 CF66KP 22.50 6.50 x 45°P (2) 6 20.00 40.00 300 300 51630 4.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 28-11 CF2500 BCF1801 CF66KP 24.25 7.00 x 45°P (2) 8 27.00 90.00 300 300 51630 4.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 28-12 CF3500A BCF1301 CF80KM 27.50 8.00 x 45°P (2) 7 30.00 90.00 300 300 51630 4.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 28-13 CF3500A BCF1301 CF114KR 29.90 9.00 x 60°P (2) 7 50.00 100.00 300 300 51631 5.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 28-4 CF1400 BCF205 CF66KE 8.00 5.00 X 45°P 2 40.00 70.00 150 300 51629 4.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 28-5 CF1400 BCF205 CF66KE 10.25 6.00 X 45°P 4 40.00 90.00 150 300 51629 4.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 28-6 CF2300A BCF304 CF66KG 12.50 7.50 X 45°P 1 20.00 40.00 150 300 51630 4.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 28-7 CF2300A BCF304 CF66KG 15.00 9.00 X 45°P 3 30.00 55.00 150 300 51630 4.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 28-8 CF2300A BCF304 CF66KG 17.50 10.00 X 45°P 5 30.00 60.00 150 300 51630 4.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers 28-9 CF2300A BCF304 CF66KS 19.60 11.00 X 45°P 3 30.00 70.00 150 300 51630 4.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers BB-14 H-7 CF500 BCF809 CF60KK 3.40 3.00 X 45°PLP 3 4.00 0.00 N/A 140 51311 2.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers BB-14 H-8 CF500 BCF809 CF60KK 4.00 3.25 x 45°PLP 5 8.00 0.00 N/A 140 51311 2.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers BB-14 L-7 CF500 BCF809 CF60KK 3.00 2.50 X 45°PLP 3 3.00 0.00 N/A 140 51311 2.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers BB-14 L-8 CF500 BCF809 CF60KK 3.50 3.00 X 45°PLP 3 5.00 0.00 N/A 140 51311 2.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers HE28-10 CF2500 BCF1801 CF66KP 20.80 6.00 X 60°P 7 21.00 45.00 300 300 51630 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers HE28-11 CF3500A BCF1301 CF92KM 22.50 6.50 X 60°P 4 24.00 50.00 300 300 51630 4.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers HE28-12 CF3500A BCF1301 CF114KR 25.10 7.50 X 60°P 5 27.00 70.00 290 290 51631 5.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers HE28-13 CF3500A BCF1301 CF114KR 27.50 8.00 X 60°P 6 30.00 70.00 290 290 51631 5.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers HE28-4 CF1400 BCF205 CF66KF 7.80 4.50 X 45°P 2 35.00 45.00 150 300 51629 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers HE28-5 CF2300A BCF304 CF66KG 9.50 5.50 X 60°P 0 18.00 28.00 150 280 51630 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers HE28-6 CF2300A BCF304 CF66KG 11.20 6.50 X 60°P 3 25.00 35.00 150 300 51630 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers HE28-7 CF2300A BCF304 CF66KG 13.90 8.00 X 60°P 6 30.00 40.00 150 280 51629 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers HE28-8 CF2500 BCF1801 CF66KP 16.40 5.00 X 45°P 1 15.00 25.00 270 270 51630 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Smith Cast Iron Boilers HE28-9 CF2500 BCF1801 CF66KP 18.20 5.50 X 45°P 5 20.00 35.00 280 280 51630 3.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Utica Boiler Starfire II 6225 CF375 BCF3907 CF100KZ 2.25 2.00 X 45°B 0 6.00 3.00 N/A 140 51311 2.250" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Utica Boiler Starfire II 7275 CF375 BCF3907 CF100KZ 2.75 2.25 X 45°B 1 4.00 5.00 N/A 140 51311 2.25" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Utica Boiler Starfire II SFM66 CF500 BCF809 CF60KK 2.25 2.00 X 60°B 1 3.00 0.00 N/A 140 51311 1.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Utica Boiler Starfire II SFM77 CF500 BCF809 CF60KK 2.75 2.50 X 60°B 2 5.50 0.00 N/A 140 51311 1.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Vaillant Corporation F200-10 CF1400 BCF205 CF66KD 5.50 3.00 x 45°S 1 20.00 35.00 150 300 51312 5.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Vaillant Corporation F200-11 CF1400 BCF205 CF66KD 6.30 3.50 x 45°S 1 28.00 55.00 150 300 51312 5.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Vaillant Corporation F200-12 CF1400 BCF205 CF66KD 7.00 4.00 x 45°S 2 28.00 80.00 150 300 51312 5.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Vaillant Corporation F200-5 CF500 BCF809 CF80KK 2.25 2.00 X 45°AS 0 3.50 0.00 N/A 140 51311 5.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Vaillant Corporation F200-6 CF500 BCF809 CF80KK 2.75 2.50 X 45°AS 1 3.50 0.00 N/A 140 51311 5.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Vaillant Corporation F200-7 CF800 BCF403 CF80KHS 3.25 2.75 X 45°AS 3 2.00 0.00 N/A 140 51311 5.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Vaillant Corporation F200-8 CF800 BCF403 CF80KHS 4.00 3.50 x 45°S 2 5.50 0.00 N/A 140 51311 5.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Vaillant Corporation F200-9 CF800 BCF403 CF80KHS 4.75 4.00 x 45°S 3 7.00 0.00 N/A 140 51311 5.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 1078 CF1400 BCF205 CF66KE 9.60 5.50 x 45°B 3 30.00 60.00 150 300 51629 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 1080 CF1400 BCF205 CF66KE 9.60 5.50 X 45°P 3 30.00 60.00 150 300 51629 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 1088 CF2500 BCF1801 CF66KP 21.50 06.50 x 60°B (D) 8 28.00 54.00 N/A 300 0 4.00" 0.5 DEGREE PITCH. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 1088 CF2500 BCF1801 CF66KP 21.50 6.00 x 60°B (2) 2 18.00 40.00 300 300 51630 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 1088R CF2300A BCF304 CF66KS 19.90 12.00 X 45°P 2 40.00 65.00 150 275 51630 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 1178 CF2300A BCF304 CF66KG 10.60 6.00 X 45°P 0 15.00 30.00 150 300 51630 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 1180 CF2300A BCF304 CF66KG 10.60 6.00 X 45°P 0 15.00 30.00 150 300 51630 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 1188 CF2500 BCF1801 CF66KP 23.50 07.00 x 45°B (D) 8 29.00 44.00 N/A 300 0 4.00" 0.5 DEGREE PITCH. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 1188 CF2500 BCF1801 CF66KP 23.50 6.50 x 60°B (2) 4 20.00 40.00 300 300 51630 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 1278 CF2300A BCF304 CF66KG 11.60 7.00 X 45°P 0 20.00 50.00 150 280 51630 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 1280 CF2300A BCF304 CF66KG 11.60 7.00 X 45°P 0 30.00 60.00 150 280 51630 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 1288 CF3500 BCF1301 CF80KM 26.00 7.50 x 60°B (2) 7 24.00 60.00 300 300 51630 4.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 1288 CF3500A BCF1301 CF80KM 26.00 07.50 x 45°B (D) 3 31.00 63.00 N/A 300 0 4.50" 0.5 DEGREE PITCH. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 1388 CF3500 BCF1301 CF80KM 28.50 8.50 x 60°B (2) 7 26.00 70.00 300 300 51630 4.50" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 1388 CF3500A BCF1301 CF80KM 28.50 08.50 x 45°B (D) 6 33.00 98.00 N/A 300 0 4.50" 0.5 DEGREE PITCH. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 1488 CF3500 BCF1301 CF114KR 29.90 9.00 x 60°B (2) 7 50.00 100.00 300 300 51631 5.375" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 378 CF500 BCF809 CF60KK 2.40 2.00 X 45°B 1 6.00 0.00 N/A 140 51311 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 380 CF500 BCF809 CF60KK 2.40 2.00 x 60°B (D) 1 4.00 0.00 N/A 140 51311 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 476 CF500 BCF809 CF60KK 2.35 2.00 X 45°B 1 4.00 0.00 N/A 140 51311 2.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 478 CF500 BCF809 CF60KK 3.40 2.75 X 45°P 4 10.00 2.00 N/A 150 51311 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 480 CF500 BCF809 CF60KK 3.40 2.75 x 45°PLP 4 10.00 3.00 N/A 150 51311 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 488 CF1400 BCF205 CF66KD 7.00 4.00 x 70°B 1 30.00 120.00 125 300 51629 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 488 CF1400 BCF205 CF66KD 7.00 04.00 x 70°B (D) 4 39.00 54.00 150 300 0 4.00" 0.5 DEGREE PITCH. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 488R CF1400 BCF205 CF66KD 6.90 4.00 x 70°B 1 30.00 120.00 125 300 51629 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 576 CF500 BCF809 CF60KK 2.95 2.50 X 45°B 3 5.00 0.00 N/A 140 51311 2.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 578 CF800 BCF403 CF60KHS 4.45 3.75 X 30°P 2 7.00 0.00 N/A 150 51311 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 580 CF800 BCF403 CF60KHS 4.45 3.75 X 30°P 2 7.00 0.00 N/A 150 51311 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 588 CF1400 BCF205 CF66KD 9.40 5.50 x 70°B 3 40.00 120.00 125 300 51629 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 588 CF2300A BCF304 CF66KG 9.40 05.50 x 60°P 0 34.00 42.00 150 300 0 4.00" 0.5 DEGREE PITCH. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 676 CF500 BCF809 CF60KK 3.60 3.00 x 45°B 5 10.00 4.00 N/A 140 51311 2.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 678 CF800 BCF403 CF60KHS 5.50 4.50 X 45°P 4 10.00 3.00 N/A 150 51311 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 680 CF800 BCF403 CF60KHS 5.50 4.50 X 45°P 4 10.00 3.00 N/A 150 51311 3.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 688 CF2300A BCF304 CF66KG 11.80 07.00 x 60°B (D) 3 41.00 51.00 150 300 0 4.00" 0.5 DEGREE PITCH. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 688 CF2300 BCF304 CF66KG 11.80 6.50 x 60°B 2 20.00 30.00 125 300 51630 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 776 CF500 BCF809 CF60KK 4.25 3.50 x 45°B 6 10.00 5.00 N/A 140 51311 2.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 778 CF1400 BCF205 CF66KD 6.50 3.75 X 45°P 3 20.00 45.00 150 300 51629 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 780 CF1400 BCF205 CF66KD 6.50 3.75 X 45°P 3 20.00 45.00 150 300 51629 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 788 CF2300A BCF304 CF66KG 14.20 8.00 x 60°B 3 20.00 30.00 125 300 51630 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 788 CF2300A BCF304 CF66KG 14.20 08.50 x 60°B (D) 6 43.00 54.00 150 280 0 4.00" 0.5 DEGREE PITCH. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 876 CF800 BCF403 CF60KH 4.90 4.00 X 45°B 1 8.00 0.00 N/A 140 51311 2.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 878 CF1400 BCF205 CF66KD 7.50 4.50 X 45°P 4 25.00 45.00 150 275 51629 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 880 CF1400 BCF205 CF66KD 7.50 4.50 X 45°P 4 25.00 45.00 150 275 51629 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 888 CF2300A BCF304 CF66KG 16.60 9.50 x 60°B 5 30.00 60.00 125 300 51630 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 888 CF2500A BCF3001 CF66KP 16.60 05.00 x 45°PLP 2 24.00 50.00 300 300 0 4 0.5 DEGREE PITCH. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 976 CF800 BCF403 CF60KH 5.50 4.50 X 45°B 3 10.00 0.00 N/A 140 51311 2.875" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 978 CF1400 BCF205 CF66KD 8.50 5.00 X 45°P 5 25.00 60.00 150 300 51629 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 980 CF1400 BCF205 CF66KD 8.50 5.00 X 45°P 5 25.00 60.00 150 300 51629 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 988 CF2300A BCF304 CF66KS 18.20 11.00 X 45°P 1 38.00 63.00 150 275 51630 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 988 CF2500A BCF3001 CF66KP 18.80 05.50 x 60°P (H) 4 27.00 52.00 N/A 300 0 4.00" 0.5 DEGREE PITCH. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Weil-McLain 988R CF2300A BCF304 CF66KG 17.20 10.00 x 60°B 8 38.00 95.00 125 300 51630 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Appliance Mfg Appliance Boiler Burner Model Chassis Part No. Air Tube Combo Nozzle Head Setting Low Fire Air or Shutter High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion Depth Note

Residential Gas Burner Specification Guide

Commercial Gas Burner Specification Guide

Beckett Training is Now Online

Informative and technical training resources from the leading experts in the heating industry

We're Here to Help!

Have questions about our products? Looking for a solution to address a particular application? Looking to improve the overall productivity and profitability of your operation? Please don’t hesitate to reach out or schedule a no obligation, 1-on-1 consultation with a Beckett Technical Specialist — we’d love to help.

Where to Buy

Beckett solutions are available through our network of Distributors, Independent Representatives, and Export Representatives all around the world.