7559

GeniSys™ 7559 24V Oil Burner Control

Category:

Product Description

The Beckett GeniSys™ 24 V Advanced Burner Control is a 24 VDC primary safety control for oil burners used on pressure washers, road stripers, crack sealers, hot patchers, and asphalt distributors, to name a few examples. The GeniSys™ 24 V is used with a suitable cad cell flame sensor to control the oil burner motor, igniter, and optional solenoid valve. It can provide interrupted or intermittent duty ignition, and it has a 15 second lockout time.

Features & Benefits

  • New Feature Programmable valve-on delay and motor-off delay provides chamber cooling after call for heat
  • Epoxy potted for moisture resistance
  • Welded relay protection with redundant motor relays
  • High ambient temperature rating
  • Alarm output enables visual or audio indication of flame failure and lock out condition
  • Interrupted ignition
  • Relight function
  • Fused protection

Technical Information Bulletins

GeniSys Contractor Tool Lockout Tech Bulletin

Inputs
  • Voltage: 24 VDC nominal (21.6 to 30 VDC)
  • Current: 220 mA plus burner motor, igniter, and valve loads
Outputs
  • Motor: : 24 VDC, 10 full load amps (FLA), 50 locked rotor amps (LRA)
  • Igniter: 24 VDC, 3 A
  • Solenoid Valve: 24 VDC, 1 A
  • Lockout Alarm: 24 VDC, 1 A
Environmental Ratings
  • Storage & Operating Ambient Temperature:: -40°F to +160°F (-40°C to +71°C)
  • Moisture: 5-95% RH, condensing

GeniSys 24V Model Guide

Beckett GeniSys Control Part No. Lockout Time Valve-on Delay Time1 Motor-off Delay Time1
7559A 0000 15 sec
7559P 1530 15 sec 15 sec 30 sec
7559P 152M 15 sec 15 sec 2 min
7559P 158M 15 sec 15 sec 8 min

1 Valve-on delay and motor-off delay timings on all models are programmable with Beckett Contractor Tool.

Literature

GeniSys 7559 24v Burner Control Manual
GeniSys 24V Product Sheet

Warranty Information