Features & Benefits
- New Feature Programmable valve-on delay and motor-off delay provides chamber cooling after call for heat
- Valve-on delay / motor-off delay (Field programmable with Beckett’s Contractor Tool)
- Epoxy potted for moisture resistance
- Welded relay protection with redundant motor relays
- High ambient temperature rating
- Alarm output enables visual or audio indication of flame failure and lock out condition
- Interrupted ignition
- Relight function
- Fused protection
- 15 second lockout time
- Communication port
Technical Information Bulletins
Inputs
- Voltage: 12 VDC nominal (11 to 16 VDC)
- Current: 160 mA nominal (500 mA max at 16 VDC)
- Enable Load: 40mA at 12 VDC
Outputs
- Motor: 12 VDC, 20 full load amps (FLA), 100 locked rotor amps (LRA)
- Igniter: 12 VDC, 5 A
- Solenoid Valve: 12 VDC, 2 A
- Lockout Alarm: 12 VDC, 2 A
Environmental Ratings
- Storage & Operating Ambient Temperature: -40°F to +160°F (-40°C to +71°C)
- Moisture: 5-95% RH, condensing
GeniSys 12V Model Guide
Beckett GeniSys Control Part No. | Lockout Time | Valve-on Delay Time2 | Motor-off Delay Time2 |
7556A 00001 | 15 sec | – | – |
7556P 15301 | 15 sec | 15 sec | 30 sec |
7556P 151M1 | 15 sec | 15 sec | 1 min |
7556P 152M1 | 15 sec | 15 sec | 2 min |
7556P 158M1 | 15 sec | 15 sec | 8 min |
1 Replaces the Beckett 7434 control.
2 Valve-on delay and motor-off delay timings on all models are programmable with Beckett Contractor Tool.