AFII Oil Burner

  • One-Piece Flame Retention Head – Special stainless steel construction for high performance. Time proven design. Has standard ceramic head insulator which prevents flame radiation upon the combustion components. Also fills entry openings in most combustion chambers which blocks infiltration of hot combustion gases.
  • ¼” Quick Connect Electrode Terminals – Fittings standard to our industry assure positive contact at all times. Easy to service.
  • Integrated Pump/Motor Assembly – Standard pumps. Motor has service friendly keyhole flange.
  • Sturdy Die-Cast Aluminum Housing – Has a smooth finish that keeps its like-new look for years.
  • Easily Read Air Control Dial – Locks in place for easy-to-set, precise air intake through a large single port. Regulates air on the discharge side of the blower.
  • Single, Big Air Inlet – Is on the opposite side of the burner, away from the pump, to fight lint buildup. Designed to accept 4″ air supply duct with inlet cover removed.

Capacities

AFII 85
  • 0.40 to 0.85 gph
  • 56,000 to 119,000 BTU/hr input
AFII 150
  • 0.75 to 1.35 gph
  • 105,000 to 189,000 BTU/hr input

Fuel Unit

  • Single stage or two stage

 Fuels

  • No. 1 or No. 2 heating oil (ASTM D396) only

Dimensions (standard)

  • Height: 13¼”
  • Width: 14½”
  • Depth: 6⅝”

Electrical Characteristics

  • Motor: 3450 rpm, NEMA M-flange, manual reset overload protection
  • Power Supply: 120 V./60Hz./1 phase
  • Ignition: 10,000 V./23 ma. secondary, continuous duty shielded transformer
  • Operating Load: 5.8 amps (maximum)
  • Alternated Voltages or Frequency: Consult Customer Service

Burner Chassis

  • Model AFII Burner Chassis
  • Fuel Unit: Beckett ‘CleanCut’ single-stage – Standard
  • Primary Control: Beckett ‘GeniSys’ – Standard

Air Tube Combination

  • Air Tube Length (dimension A) and Firing Rate or Air Tube Combination Code (see table).

Accessories

  • Specify Mounting flange – See Below
  • Add any other items such as spare parts, related controls, valves, control panels, etc.

Air Tube Combination Chart

USABLE AIR TUBE LENGTH DIMENSION AAFII 85 FIRING RATE IN GPHAFII 150 FIRING RATE IN GPH
.40-.65.55-.85.75-1.00.85-1.201.10-1.251.15-1.35
5″FBX50HFXSFBX50HGXSFBX50HFXSFBX50HGXSFBX50HHXSFBX50HIXS
7″FBX70HFXSFBX70HGXSFBX70HFXSFBX70HGXSFBX70HHXSFBX70HIXS
9″FBX90HFXSFBX90HGXSFBX90HFXSFBX90HGXSFBX90HHXSFBX90HIXS
To Determine Air Tube Length

100
The Air Tube Length (Dimension A) is the distance from the front of the burner housing to the end of the tube.

Adjustable Mounting Flange Kit

102

No. 51480 Adjustable Mounting Flange Kit – A one-piece flange. Includes a flange mounting gasket.

Flame Retention Heads

AFII Heads

AFII Burner Manual

Warranty Information